Pokaż uproszczony rekord

dc.contributor.authorWrzesień, Małgorzata
dc.contributor.authorAlbiniak, Łukasz
dc.contributor.authorKrólicki, L.
dc.contributor.authorOlszewski, J.
dc.date.accessioned2021-08-31T06:56:07Z
dc.date.available2021-08-31T06:56:07Z
dc.date.issued2019
dc.identifier.isbn978-86-81652-01-5
dc.identifier.urihttp://hdl.handle.net/11089/38965
dc.description.abstractBackground: Changing the individual dose limit for the lens of the eye from a value of 150 mSv per year to a level of 20 mSv (averaged over defined periods of five years or 50 mSv in a single year) means that issues related to routine eye lens dosimetry become interesting from the point of view of radiation protection. This could mean that the dosimeter designed to measure the doses at the level of the eye lens may become the next dosimeter routinely worn by nuclear medicine workers occupationally exposed to ionising radiation. The dosimeters currently used in nuclear medicine are the personal dosimeter and the ring dosimeter. Will this also be the case for nuclear medicine employees? In this interdisciplinary branch of medicine, the factors that cause the highest risk of radiation exposure of personnel are the process of manual handling, i.e. the process of preparing a radiopharmaceutical called labelling. Most of the radiopharmaceuticals used in nuclear medicine are labelled manually. In Poland, the exception from this rule is when radiopharmaceuticals are produced for the needs of positron emission tomography (PET), which are labelled using automatic processes. Manual procedures also include the process of radiopharmaceutical injection to the patients. The aim of the work was to assess the exposure of eye lenses of workers in nuclear medicine, as well as of the personnel in centers that produce radiopharmaceuticals for PET diagnostics, from the viewpoint of advisability of routine eye lens exposure monitoring, taking into account changes in the dose limit for the lens of the eye. Methods: The results of own measurements of the personal dose equivalent Hp(3), carried out in five nuclear medicine departments in Poland, as well as in two centers producing radiopharmaceuticals for PET, were subject to analysis. The analysis includes two most frequently used radionuclides for diagnostic purposes, namely 99mTc, 18F and the less frequently used 68Ga, in addition to 131I, which is used for therapeutic purposes. Dosimetric measurements were made using thermoluminescent detectors of domestic manufacture. Results & Conclusions: Estimated analysis of the annual exposure makes it possible to indicate cases where the maximum annual value of personal dose equivalent, in terms of Hp(3), exceeds threefold the new limit value specified at 20 mSv/year.pl_PL
dc.language.isoenpl_PL
dc.publisherSievert Associationpl_PL
dc.relation.ispartofRAP Conference Proceedings;4
dc.rightsUznanie autorstwa 4.0 Międzynarodowe*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectdose limitpl_PL
dc.subjectdosimetrypl_PL
dc.subjecteye lenspl_PL
dc.subjectHp(3)pl_PL
dc.subjectnuclear medicinepl_PL
dc.subjectradionuclidepl_PL
dc.subjectradiopharmaceuticalpl_PL
dc.titleA need for eye lens dosimetry in nuclear medicinepl_PL
dc.typeOtherpl_PL
dc.page.number67-71pl_PL
dc.contributor.authorAffiliationUniversity of Lodz, Faculty of Physics and Applied Informatics, Department of Nuclear Physics and Radiation Safety, Lodz, Polandpl_PL
dc.contributor.authorAffiliationUniversity of Lodz, Faculty of Physics and Applied Informatics, Department of Nuclear Physics and Radiation Safety, Lodz, Polandpl_PL
dc.contributor.authorAffiliationMedical University Warsaw, Nuclear Medicine Department, Warsaw, Polandpl_PL
dc.contributor.authorAffiliationNofer Institute of Occupational Medicine, Department of Radiation Protection, Lodz, Polandpl_PL
dc.identifier.eissn2466-4626
dc.referencesICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs— threshold doses for tissue reactions in a radiation protection context, vol. 41, ICRP Publication no. 118, ICRP, Ottawa, Canada, 2012. DOI: 10.1016/j.icrp.2012.02.001pl_PL
dc.referencesThe 2007 Recommendations of the International Commission on Radiological Protection, vol. 37, ICRP Publication no. 103, ICRP, Ottawa, Canada, 2007. Retrieved from: https://journals.sagepub.com/doi/pdf/10.1177/ANIB_ 37_2-4pl_PL
dc.referencesImplications for Occupational Radiation Protection of the New Dose Limit for the Lens of the Eye, TECDOC No. 1731, IAEA, Vienna, Austria, 2013. Retrieved from: https://wwwpub.iaea.org/MTCD/Publications/PDF/TE1731_web.pdfpl_PL
dc.referencesJ. Dabin et al., “Eye lens doses in nuclear medicine: A multicentric study in Belgium and Poland,” Radiat. Prot. Dosim., vol. 170, no. 1 – 4, pp. 297 – 301, Sep. 2016. DOI: 10.1093/rpd/ncv538pl_PL
dc.referencesS. Leide-Svegborn, “External radiation exposure of personnel in nuclear medicine from 18F, 99mTc and 131I with special reference to fingers, eyes and thyroid,” Radiat. Prot. Dosim., vol. 149, no. 2, pp. 196 – 206, Apr. 2012. DOI: 10.1093/rpd/ncr213pl_PL
dc.referencesMateriały i sprzęt ochronny przed promieniowaniem X i gamma -- Obliczanie osłon stałych, PN-86/J80001, Czerwiec 10, 1986. (Materials and equipment protection against X-rays and gamma rays. Calculation the thickness of shields used against ionizing radiation, PN-86/J-80001, Jun. 10, 1986.)pl_PL
dc.referencesK. A. Pachocki, A. Sackiewicz-Słaby, “Determining the current status and potential of nuclear medicine in Poland,” Rocz. Państw. Zakł. Hig., vol. 64, no. 3, pp. 243 – 250, 2013. Retrieved from: http://wydawnictwa.pzh.gov.pl/roczniki_pzh/downloa d-article?id=992pl_PL
dc.referencesStan zdrowia ludnoœci polski w 2004 r., Główny urząd statystyczny, Warszawa, Polska, 2006. (The health status of the Polish population in 2004, Central Statistical Office, Warsaw, Poland, 2006.) Retrieved from: https://stat.gov.pl/cps/rde/xbcr/gus/stan_zdrowia_20 04.pdfpl_PL
dc.referencesX and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy, part 1, ISO Report 4037–1, ISO, Geneva, Switzerland, 1997.pl_PL
dc.referencesX and gamma reference radiation for calibrating dosemeters and doserate meters and determining their response as a function of photon energy, part 3, ISO Report 4037–3, ISO, Geneva, Switzerland, 1999. Retrieved from: https://www.sis.se/api/document/preview/615127/pl_PL
dc.referencesF. Vanhavere et al., “Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project,” Radiat. Meas., vol. 46, no. 11, pp. 1243 – 1247, Nov. 2011. DOI: 10.1016/j.radmeas.2011.08.013pl_PL
dc.referencesF. Vanhavere et al., ORAMED: Optimization of radiation protection of medical staff, Rep. 2012-02, EURADOS, Braunschweig, Germany, 2012. Retrieved from: https://eurados.sckcen.be/- /media/Files/Eurados/documents/EURADOS_Report _201202.pdf?la=en&hash=06DAE419D9DE476193197 19264086015D1D9143Epl_PL
dc.referencesM. Wrzesień, “18F-FDG production procedures as a source of eye lens exposure to radiation,” J. Radiol. Prot., vol. 38, no. 1, pp. 382 – 393, Feb. 2018. DOI: 10.1088/1361-6498/aaa287pl_PL
dc.referencesM. Wrzesień, L. Królicki, Ł. Albiniak, J. Olszewski, “Is eye lens dosimetry needed in nuclear medicine?,” J. Radiol. Prot., vol. 38, no. 2, pp. 763 – 774, Jun. 2018. DOI: 10.1088/1361-6498/aabef5pl_PL
dc.referencesM. Wrzesień, Ł. Albiniak, “68Ga-DOTA-TATE—a source of eye lens exposure for nuclear medicine department workers,” J. Radiol. Prot., vol. 38, no. 4, pp. 1512 – 1523, Dec. 2018. DOI: 10.1088/1361-6498/aaea8epl_PL
dc.referencesThe Council of European Union. (Dec. 5, 2013). Council Directive 2013/59/EURATOM. Laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation, and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom. Retrieved from: https://eurlex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:20 14:013:0001:0073:EN:PDFpl_PL
dc.contributor.authorEmailmalgorzata.wrzesien@uni.lodz.plpl_PL
dc.identifier.doi10.37392/RapProc.2019.14
dc.disciplinenauki medycznepl_PL
dc.disciplinenauki o zdrowiupl_PL
dc.disciplinenauki fizycznepl_PL