Notes on the Optimum Chemical Balance Weighing Design
Abstract
In the paper, the model of the chemical balance weighing design, i.e. model in that
the result of experiment we can describe as linear function of unknown measurements of objects
with known factors, is presented. Additionally, we assume that the measurement errors are
uncorrelated and they have different variances. The problem is to estimate unknown measurements
of objects. The existence conditions setting the optimum design and new construction method of
the matrix determining the conditions of the experiment, are presented.